{"product_id":"asab-p-series-1-4-bsp-pneumatic-regulator","title":"ASAB P Series - 1\/4\" BSP Pneumatic Regulator","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003carticle data-turn=\"assistant\" data-scroll-anchor=\"true\" data-testid=\"conversation-turn-74\" data-turn-id=\"request-699fb776-2ecc-8399-9934-85dea0dd06b2-5\" dir=\"auto\" class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm\/main:[--thread-content-margin:--spacing(6)] @w-lg\/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\" data-message-model-slug=\"gpt-5-2-thinking\" dir=\"auto\" data-message-id=\"d9073340-ed7c-4208-8309-0757af56c8bc\" data-message-author-role=\"assistant\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cp data-end=\"29\" data-start=\"0\"\u003e\u003cstrong\u003ePart Code: ASAB-PFR1\/4-49\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"394\" data-start=\"31\"\u003eIntroducing the \u003cstrong data-end=\"89\" data-start=\"47\"\u003eASAB Pneumatic Regulator \u003c\/strong\u003e — a compact, reliable pneumatic regulator designed to deliver \u003cstrong data-end=\"190\" data-start=\"152\"\u003estable, adjustable outlet pressure\u003c\/strong\u003e for workshop and site air systems. Ideal for point-of-use air control, it helps keep downstream tools and equipment running consistently by smoothing out supply fluctuations and preventing over-pressure.\u003c\/p\u003e\n\u003cp data-end=\"745\" data-start=\"396\"\u003eWith \u003cstrong data-end=\"419\" data-start=\"401\"\u003e1\/4\" BSP ports\u003c\/strong\u003e, the ASAB-PFR1\/4-49 suits common Australian pneumatic plumbing and is a handy fit for air boards, benches, spray equipment, and diaphragm pump air feeds where you want dependable control in a smaller format. Rated to \u003cstrong data-end=\"648\" data-start=\"637\"\u003e150 PSI\u003c\/strong\u003e, it’s built for everyday compressed air applications where accurate pressure management matters.\u003c\/p\u003e\n\u003cp data-end=\"989\" data-start=\"747\"\u003eWhether you’re replacing a regulator that won’t hold pressure, setting up a tidy air control station, or standardising fittings across the workshop, the \u003cstrong data-end=\"89\" data-start=\"47\"\u003eASAB Pneumatic Regulator\u003c\/strong\u003e is a practical, job-site-ready solution for dependable air regulation.\u003c\/p\u003e\n\u003ch2 data-end=\"1011\" data-start=\"996\"\u003eKey Benefits\u003c\/h2\u003e\n\u003cul data-end=\"1510\" data-start=\"1013\"\u003e\n\u003cli data-end=\"1076\" data-start=\"1013\"\u003e\n\u003cp data-end=\"1076\" data-start=\"1015\"\u003e\u003cstrong data-end=\"1035\" data-start=\"1015\"\u003eRated to 150 PSI\u003c\/strong\u003e for common compressed air applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1145\" data-start=\"1077\"\u003e\n\u003cp data-end=\"1145\" data-start=\"1079\"\u003e\u003cstrong data-end=\"1097\" data-start=\"1079\"\u003e1\/4\" BSP ports\u003c\/strong\u003e for standard Australian pneumatic connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1234\" data-start=\"1146\"\u003e\n\u003cp data-end=\"1234\" data-start=\"1148\"\u003eProvides \u003cstrong data-end=\"1195\" data-start=\"1157\"\u003estable, adjustable outlet pressure\u003c\/strong\u003e for consistent equipment performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1310\" data-start=\"1235\"\u003e\n\u003cp data-end=\"1310\" data-start=\"1237\"\u003eHelps protect downstream gear from \u003cstrong data-end=\"1308\" data-start=\"1272\"\u003epressure spikes and fluctuations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1396\" data-start=\"1311\"\u003e\n\u003cp data-end=\"1396\" data-start=\"1313\"\u003eIdeal for \u003cstrong data-end=\"1350\" data-start=\"1323\"\u003epoint-of-use regulation\u003c\/strong\u003e on benches, air boards, and equipment feeds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1455\" data-start=\"1397\"\u003e\n\u003cp data-end=\"1455\" data-start=\"1399\"\u003eCompact format suits tight installs and service panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1510\" data-start=\"1456\"\u003e\n\u003cp data-end=\"1510\" data-start=\"1458\"\u003eDurable construction for workshop and job-site use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1535\" data-start=\"1517\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul data-end=\"1602\" data-start=\"1537\"\u003e\n\u003cli data-end=\"1602\" data-start=\"1537\"\u003e\n\u003cp data-end=\"1602\" data-start=\"1539\"\u003e\u003cstrong data-end=\"1581\" data-start=\"1539\"\u003eASAB Regulator 1\/4\" BSP (150 PSI) – 49\u003c\/strong\u003e — \u003cstrong data-end=\"1602\" data-start=\"1584\"\u003eASAB-PFR1\/4-49\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"1626\" data-start=\"1609\"\u003eSafety Check\u003c\/h2\u003e\n\u003cul data-end=\"2399\" data-start=\"1628\"\u003e\n\u003cli data-end=\"1763\" data-start=\"1628\"\u003e\n\u003cp data-end=\"1763\" data-start=\"1630\"\u003e\u003cstrong data-end=\"1665\" data-start=\"1630\"\u003eIsolate and depressurise first:\u003c\/strong\u003e Shut off air supply, bleed the line fully, and confirm pressure is at zero before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1859\" data-start=\"1764\"\u003e\n\u003cp data-end=\"1859\" data-start=\"1766\"\u003e\u003cstrong data-end=\"1790\" data-start=\"1766\"\u003eConfirm thread type:\u003c\/strong\u003e Ensure mating fittings are \u003cstrong data-end=\"1830\" data-start=\"1818\"\u003e1\/4\" BSP\u003c\/strong\u003e (do not mix BSP with NPT).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2011\" data-start=\"1860\"\u003e\n\u003cp data-end=\"2011\" data-start=\"1862\"\u003e\u003cstrong data-end=\"1893\" data-start=\"1862\"\u003eUse correct sealing method:\u003c\/strong\u003e BSPP typically seals with a \u003cstrong data-end=\"1944\" data-start=\"1922\"\u003ebonded seal\/washer\u003c\/strong\u003e; BSPT seals on the thread taper—match your fittings accordingly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2123\" data-start=\"2012\"\u003e\n\u003cp data-end=\"2123\" data-start=\"2014\"\u003e\u003cstrong data-end=\"2052\" data-start=\"2014\"\u003eInstall in correct flow direction:\u003c\/strong\u003e Follow \u003cstrong data-end=\"2079\" data-start=\"2060\"\u003eIN\/OUT markings\u003c\/strong\u003e (if present) to ensure proper regulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2277\" data-start=\"2124\"\u003e\n\u003cp data-end=\"2277\" data-start=\"2126\"\u003e\u003cstrong data-end=\"2152\" data-start=\"2126\"\u003ePressure up gradually:\u003c\/strong\u003e Bring air pressure up slowly and leak test with \u003cstrong data-end=\"2216\" data-start=\"2201\"\u003esoapy water\u003c\/strong\u003e—don’t check leaks with your hands near pressurised joints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2399\" data-start=\"2278\"\u003e\n\u003cp data-end=\"2399\" data-start=\"2280\"\u003e\u003cstrong data-end=\"2304\" data-start=\"2280\"\u003eStay within ratings:\u003c\/strong\u003e Make sure the regulator and downstream components are rated for the intended working pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong data-is-last-node=\"\" data-end=\"2459\" data-start=\"2406\"\u003eASAB – Engineered for Performance, Built to Last.\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e","brand":"Australian Spray \u0026 Blast","offers":[{"title":"Default Title","offer_id":48344532975831,"sku":"ASAB-PFR1\/4-49","price":88.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/9925\/4743\/files\/PNEUMATICREGULATOR1-4INCH.jpg?v=1772591080","url":"https:\/\/asab.au\/products\/asab-p-series-1-4-bsp-pneumatic-regulator","provider":"Australian Spray \u0026 Blast","version":"1.0","type":"link"}