{"product_id":"asab-s3-s7-s8-transducer","title":"ASAB S Series - Replacement S3\/S7\/S8 Transducer","description":"\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003carticle class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:0947b895-7267-427a-b7ec-2d60aab9c5b7-35\" data-testid=\"conversation-turn-34\" data-scroll-anchor=\"true\" data-turn=\"assistant\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:--spacing(4)] @w-sm\/main:[--thread-content-margin:--spacing(6)] @w-lg\/main:[--thread-content-margin:--spacing(16)] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"f3242948-ffe6-4c63-b462-f86397d779d8\" dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\" data-message-model-slug=\"gpt-5-2-thinking\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden first:pt-[1px]\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cp data-start=\"0\" data-end=\"309\"\u003eThe \u003cstrong data-start=\"36\" data-end=\"59\"\u003eS3\/S7\/S8 Transducer\u003c\/strong\u003e is the sprayer’s pressure-sensing workhorse. It reads fluid pressure in the system and feeds that information back to the control board, allowing the machine to \u003cstrong data-start=\"221\" data-end=\"253\"\u003eregulate pressure accurately\u003c\/strong\u003e, respond to demand, and maintain a steady spray output.\u003c\/p\u003e\n\u003cp data-start=\"311\" data-end=\"695\"\u003eWhen a transducer starts playing up, you’ll often see \u003cstrong data-start=\"365\" data-end=\"395\"\u003eerratic pressure behaviour\u003c\/strong\u003e, \u003cstrong data-start=\"397\" data-end=\"416\"\u003esurging\/pulsing\u003c\/strong\u003e, \u003cstrong data-start=\"418\" data-end=\"448\"\u003einconsistent spray pattern\u003c\/strong\u003e, or \u003cstrong data-start=\"453\" data-end=\"511\"\u003efault codes\/pressure readouts that don’t match reality\u003c\/strong\u003e. Replacing the transducer is a common, effective fix for pressure control issues—especially when the pump and valves check out fine but the machine still can’t hold a stable pressure.\u003c\/p\u003e\n\u003cp data-start=\"697\" data-end=\"713\"\u003e\u003cstrong data-start=\"697\" data-end=\"713\"\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"714\" data-end=\"1034\"\u003e\n\u003cli data-start=\"714\" data-end=\"773\"\u003e\n\u003cp data-start=\"716\" data-end=\"773\"\u003eAccurate \u003cstrong data-start=\"725\" data-end=\"746\"\u003epressure feedback\u003c\/strong\u003e for stable sprayer control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"774\" data-end=\"842\"\u003e\n\u003cp data-start=\"776\" data-end=\"842\"\u003eHelps restore consistent pressure regulation and smoother spraying\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"843\" data-end=\"970\"\u003e\n\u003cp data-start=\"845\" data-end=\"970\"\u003eIdeal replacement for symptoms like \u003cstrong data-start=\"881\" data-end=\"905\"\u003epressure fluctuation\u003c\/strong\u003e, \u003cstrong data-start=\"907\" data-end=\"938\"\u003eunreliable pressure control\u003c\/strong\u003e, or \u003cstrong data-start=\"943\" data-end=\"970\"\u003epressure-related faults\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"971\" data-end=\"1034\"\u003e\n\u003cp data-start=\"973\" data-end=\"1034\"\u003eSuits \u003cstrong data-start=\"979\" data-end=\"1000\"\u003eASAB S3 \/ S7 \/ S8\u003c\/strong\u003e systems (configuration dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1036\" data-end=\"1055\"\u003e\u003cstrong data-start=\"1036\" data-end=\"1055\"\u003eWhat’s included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1056\" data-end=\"1098\"\u003e\n\u003cli data-start=\"1056\" data-end=\"1098\"\u003e\n\u003cp data-start=\"1058\" data-end=\"1098\"\u003e\u003cstrong data-start=\"1058\" data-end=\"1076\"\u003e1 x Transducer\u003c\/strong\u003e (service replacement)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1100\" data-end=\"1118\"\u003e\u003cstrong data-start=\"1100\" data-end=\"1118\"\u003eSafety Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1119\" data-end=\"1708\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"1119\" data-end=\"1245\"\u003e\n\u003cp data-start=\"1121\" data-end=\"1245\"\u003e\u003cstrong data-start=\"1121\" data-end=\"1151\"\u003eRelieve all fluid pressure\u003c\/strong\u003e before removing or fitting the transducer (follow the sprayer’s pressure relief procedure).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1246\" data-end=\"1338\"\u003e\n\u003cp data-start=\"1248\" data-end=\"1338\"\u003e\u003cstrong data-start=\"1248\" data-end=\"1265\"\u003eIsolate power\u003c\/strong\u003e (unplug\/disconnect) before servicing electrical or control components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1339\" data-end=\"1454\"\u003e\n\u003cp data-start=\"1341\" data-end=\"1454\"\u003e\u003cstrong data-start=\"1341\" data-end=\"1354\"\u003eWear PPE:\u003c\/strong\u003e eye protection and chemical-resistant gloves—residual pressure and fluids can still surprise you.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1455\" data-end=\"1558\"\u003e\n\u003cp data-start=\"1457\" data-end=\"1558\"\u003e\u003cstrong data-start=\"1457\" data-end=\"1478\"\u003eInjection hazard:\u003c\/strong\u003e never check for leaks with your hand; high-pressure fluid can penetrate skin.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1559\" data-end=\"1708\" data-is-last-node=\"\"\u003e\n\u003cp data-start=\"1561\" data-end=\"1708\" data-is-last-node=\"\"\u003e\u003cstrong data-start=\"1561\" data-end=\"1592\"\u003eCheck for leaks on restart:\u003c\/strong\u003e prime at low pressure first, confirm the transducer port seals correctly, then return to normal operating pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e","brand":"Australian Spray \u0026 Blast","offers":[{"title":"Default Title","offer_id":48301259718871,"sku":"ASAB-SS3.S7.S8-23","price":108.9,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/9925\/4743\/files\/S3-S7-S8TRANSDUCER.jpg?v=1771393659","url":"https:\/\/asab.au\/products\/asab-s3-s7-s8-transducer","provider":"Australian Spray \u0026 Blast","version":"1.0","type":"link"}