{"product_id":"asab-stainless-steel-double-threaded-suction-filters","title":"ASAB P Series - Replacement SS Pneumatic Double Threaded Suction Filter","description":"\u003cp data-start=\"0\" data-end=\"45\"\u003e\u003cstrong\u003ePart Codes: ASAB-SPSS1 \/ ASAB-SPSS3\/4\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"47\" data-end=\"470\"\u003eIntroducing the \u003cstrong data-start=\"63\" data-end=\"119\"\u003eASAB Stainless Steel Double Threaded Suction Filters\u003c\/strong\u003e — heavy-duty inlet filters designed to protect your pump by catching debris \u003cstrong data-start=\"196\" data-end=\"248\"\u003ebefore it reaches valves, seats, and the wet end\u003c\/strong\u003e. Built for professional spray and transfer setups, these filters help reduce \u003cstrong data-start=\"326\" data-end=\"370\"\u003eblockages, pulsation, and premature wear\u003c\/strong\u003e, especially when drawing from drums, IBCs, or open containers where contamination is always a risk.\u003c\/p\u003e\n\u003cp data-start=\"472\" data-end=\"671\"\u003eThese suction filters feature a \u003cstrong data-start=\"504\" data-end=\"534\"\u003edouble threaded connection\u003c\/strong\u003e (threaded both ends) for a secure, service-friendly install, and are available in \u003cstrong data-start=\"617\" data-end=\"637\"\u003etwo common sizes\u003c\/strong\u003e to suit typical suction plumbing:\u003c\/p\u003e\n\u003cul data-start=\"672\" data-end=\"727\"\u003e\n\u003cli data-section-id=\"1jfdbkx\" data-start=\"672\" data-end=\"697\"\u003e\n\u003cp data-start=\"674\" data-end=\"697\"\u003e\u003cstrong data-start=\"674\" data-end=\"680\"\u003e1\"\u003c\/strong\u003e — \u003cstrong data-start=\"683\" data-end=\"697\"\u003eASAB-SPSS1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"l7awgx\" data-start=\"698\" data-end=\"727\"\u003e\n\u003cp data-start=\"700\" data-end=\"727\"\u003e\u003cstrong data-start=\"700\" data-end=\"708\"\u003e3\/4\"\u003c\/strong\u003e — \u003cstrong data-start=\"711\" data-end=\"727\"\u003eASAB-SPSS3\/4\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"729\" data-end=\"1056\"\u003eThe \u003cstrong data-start=\"733\" data-end=\"765\"\u003estainless steel construction\u003c\/strong\u003e makes them ideal for harsh job-site conditions and repeated cleaning cycles. Whether you’re replacing a damaged filter, upgrading from a basic screen, or standardising your suction setups across multiple rigs, the ASAB SS double threaded suction filters are a practical reliability upgrade.\u003c\/p\u003e\n\u003cp data-start=\"1058\" data-end=\"1219\"\u003eWhether you’re running airless sprayers, diaphragm pumps, or transfer systems, these filters are a job-site-ready solution for cleaner flow and longer pump life.\u003c\/p\u003e\n\u003ch2 data-section-id=\"17xbmye\" data-start=\"1226\" data-end=\"1241\"\u003eKey Benefits\u003c\/h2\u003e\n\u003cul data-start=\"1243\" data-end=\"1733\"\u003e\n\u003cli data-section-id=\"k2d784\" data-start=\"1243\" data-end=\"1315\"\u003e\n\u003cp data-start=\"1245\" data-end=\"1315\"\u003eProtects pumps and valves by filtering debris at the \u003cstrong data-start=\"1298\" data-end=\"1315\"\u003esuction inlet\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mxtn8\" data-start=\"1316\" data-end=\"1387\"\u003e\n\u003cp data-start=\"1318\" data-end=\"1387\"\u003e\u003cstrong data-start=\"1318\" data-end=\"1350\"\u003eStainless steel construction\u003c\/strong\u003e for durability and repeated cleaning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10ehx30\" data-start=\"1388\" data-end=\"1477\"\u003e\n\u003cp data-start=\"1390\" data-end=\"1477\"\u003e\u003cstrong data-start=\"1390\" data-end=\"1430\"\u003eDouble threaded (threaded both ends)\u003c\/strong\u003e design for secure fitment and easier servicing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10e3g4o\" data-start=\"1478\" data-end=\"1559\"\u003e\n\u003cp data-start=\"1480\" data-end=\"1559\"\u003eHelps reduce \u003cstrong data-start=\"1493\" data-end=\"1535\"\u003eblockages, pulsation, and prime issues\u003c\/strong\u003e caused by contamination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"137o9h1\" data-start=\"1560\" data-end=\"1611\"\u003e\n\u003cp data-start=\"1562\" data-end=\"1611\"\u003eIdeal for \u003cstrong data-start=\"1572\" data-end=\"1604\"\u003edrum, IBC, and bucket pickup\u003c\/strong\u003e setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10ewa1s\" data-start=\"1612\" data-end=\"1684\"\u003e\n\u003cp data-start=\"1614\" data-end=\"1684\"\u003eAvailable in \u003cstrong data-start=\"1627\" data-end=\"1633\"\u003e1\"\u003c\/strong\u003e and \u003cstrong data-start=\"1638\" data-end=\"1646\"\u003e3\/4\"\u003c\/strong\u003e sizes to suit common suction plumbing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n2q6ed\" data-start=\"1685\" data-end=\"1733\"\u003e\n\u003cp data-start=\"1687\" data-end=\"1733\"\u003eBuilt for commercial workshop and job-site use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"xydb7h\" data-start=\"1740\" data-end=\"1758\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul data-start=\"1760\" data-end=\"1904\"\u003e\n\u003cli data-section-id=\"1ycvzss\" data-start=\"1760\" data-end=\"1833\"\u003e\n\u003cp data-start=\"1762\" data-end=\"1833\"\u003e\u003cstrong data-start=\"1762\" data-end=\"1809\"\u003eASAB SS Double Threaded Suction Filter – 1\"\u003c\/strong\u003e — \u003cstrong data-start=\"1812\" data-end=\"1826\"\u003eASAB-SPSS1\u003c\/strong\u003e \u003cem data-start=\"1827\" data-end=\"1833\"\u003e(or)\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13vg24g\" data-start=\"1834\" data-end=\"1904\"\u003e\n\u003cp data-start=\"1836\" data-end=\"1904\"\u003e\u003cstrong data-start=\"1836\" data-end=\"1885\"\u003eASAB SS Double Threaded Suction Filter – 3\/4\"\u003c\/strong\u003e — \u003cstrong data-start=\"1888\" data-end=\"1904\"\u003eASAB-SPSS3\/4\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1fz9trz\" data-start=\"1911\" data-end=\"1928\"\u003eSafety Check\u003c\/h2\u003e\n\u003cul data-start=\"1930\" data-end=\"2724\"\u003e\n\u003cli data-section-id=\"7svhnq\" data-start=\"1930\" data-end=\"2077\"\u003e\n\u003cp data-start=\"1932\" data-end=\"2077\"\u003e\u003cstrong data-start=\"1932\" data-end=\"1967\"\u003eDepressurise and isolate first:\u003c\/strong\u003e Shut down the unit, relieve pressure, and ensure the suction line isn’t under vacuum\/pressure before removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1oxjcha\" data-start=\"2078\" data-end=\"2231\"\u003e\n\u003cp data-start=\"2080\" data-end=\"2231\"\u003e\u003cstrong data-start=\"2080\" data-end=\"2113\"\u003eConfirm thread type and size:\u003c\/strong\u003e Match the filter size (\u003cstrong data-start=\"2137\" data-end=\"2151\"\u003e1\" or 3\/4\"\u003c\/strong\u003e) and thread standard to your suction plumbing — don’t force mismatched threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xv5p1r\" data-start=\"2232\" data-end=\"2336\"\u003e\n\u003cp data-start=\"2234\" data-end=\"2336\"\u003e\u003cstrong data-start=\"2234\" data-end=\"2260\"\u003eKeep seal faces clean:\u003c\/strong\u003e Dirty threads or damaged sealing faces can pull air and cause prime issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"e093j3\" data-start=\"2337\" data-end=\"2477\"\u003e\n\u003cp data-start=\"2339\" data-end=\"2477\"\u003e\u003cstrong data-start=\"2339\" data-end=\"2359\"\u003eClean regularly:\u003c\/strong\u003e A blocked suction filter will starve the pump and cause cavitation\/surging — clean it as part of routine maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1uhxc0o\" data-start=\"2478\" data-end=\"2602\"\u003e\n\u003cp data-start=\"2480\" data-end=\"2602\"\u003e\u003cstrong data-start=\"2480\" data-end=\"2518\"\u003eCheck for air leaks after install:\u003c\/strong\u003e Prime and confirm steady flow with no bubbles before returning to normal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11ureb5\" data-start=\"2603\" data-end=\"2724\"\u003e\n\u003cp data-start=\"2605\" data-end=\"2724\"\u003e\u003cstrong data-start=\"2605\" data-end=\"2632\"\u003eDon’t run damaged mesh:\u003c\/strong\u003e Replace if crushed, split, or deformed — debris will get through and chew out valves\/seats.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2731\" data-end=\"2784\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\u003cstrong data-start=\"2731\" data-end=\"2784\" data-is-last-node=\"\"\u003eASAB – Engineered for Performance, Built to Last.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Australian Spray \u0026 Blast","offers":[{"title":"3\/4\"","offer_id":48344669356247,"sku":"ASAB-SPSS3\/4","price":33.0,"currency_code":"AUD","in_stock":true},{"title":"1\"","offer_id":48344669389015,"sku":"ASAB-SPSS1","price":33.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0735\/9925\/4743\/files\/PNEUMATICSUCTIONFILTER_e4bde4e4-f7af-49ec-b614-be069b366f5b.jpg?v=1772592933","url":"https:\/\/asab.au\/products\/asab-stainless-steel-double-threaded-suction-filters","provider":"Australian Spray \u0026 Blast","version":"1.0","type":"link"}